Command Descriptions
2-124
Parameter(s)
< Table 6-2-3 > Reply SE Operation Parameter(s) Field (Continued)
Parameter / PID / Size
Options
Descriptions
Laser Aiming Control
PID : 02h 09h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable
Enable *
LED Illumination
PID : 02h 0Bh
Size : 00h 01h (1 Byte)
- 00h
- 01h
Always on
Intelligent Scanning *
Illumination Delay Duration
PID : 02h 0Ch
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
100ms
200ms
300ms
400ms
500ms
.
Warning
1.
LED Illumination, Illumination Delay Duration are only available for SE390 and SE480 series.
2.
Laser Aiming Control is only available for SE398 and SE488