Store configuration – Cino FA470 User Manual
Page 35

Command Descriptions
2-20
Store Configuration
(ALL)
Descriptions
Save current settings into flash memory permanently
Note that this command is not available for storing the following settings: the beep sequence set by
Beeping command; trigger status set by Serial Trigger command and LED status set by Indicator
command.
Packet Format
Prefix
Opcode
Status
Length
Parameter(s)
LRC
Suffix
7Eh
80h 03h 00h
00h
00h 00h
<Null>
83h
7Eh
1 Byte
3 Bytes
1 Byte
2 Bytes
0 Byte
1 Byte
1 Byte
. Host Requirements
If the device successfully received the above command issued by the host, a “Device ACK” will be sent
to the host right after the device performed the action. Otherwise, a “Device NAK” will be sent to host to
issue a command error. However, if the host can not receive any response from the device within the
user preset time-out duration, please resend the above command.
. Parameter(s) Field
Store Configuration command takes no parameters, so the Parameter(s) field is null.
. Length
Total size (bytes) of the Parameter(s) field
. LRC
”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”