Cino FA470 User Manual
Page 138

Command Descriptions
2-123
Parameter(s)
< Table 6-2-3 > Reply SE Operation Parameter(s) Field (Continued)
Parameter / PID / Size
Options
Descriptions
Power on beep
PID : 01h 01h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Enable (SE380/SE388-9 *)
Disable (SE380/SE388-0, SE380/SE388-1 *)
Good Read Duration
PID : 01h 04h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
Short
Medium *
Long
Extremely long
Extremely short
Good Read Indicator
PID : 01h 05h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable(SE380-0,SE380-1,SE390-0,SE390-1,
SE480-0, SE480-1*)
Enable(SE380-9,SE390-9, SE480-9 *)
1D Barcode Inverse Reading
PID : 02h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Dollar Sign Control
PID : 02h 01h
Size : 00h 01h (1 Byte)
- 00h
- 80h
- A2h
- A3h
- A5h
Output as “$” *
Output as “€“
Output as “¢“
Output as “£“
Output as “
¥”
Redundancy
PID : 02h 02h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
None
1 time *
2 times
3 times
4 times
5 times
Data Transmission Packet
PID : 02h 04h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
UPC/EAN Security Level
PID : 02h 06h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
Level 0
Level 1 *
Level 2
Supplement Scan Voting
PID : 02h 08h
Size : 00h 01h (1 Byte)
- 00h
- 06h
- 08h
- 0Ah
- 0Ch
- 0Eh
- 10h
- 12h
- 14h
- 16h
- 18h
- 1Ah
- 1Ch
- 1Eh
None
Level 1
Level 2
Level 3 *
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13
Operation Mode (Scan Engine)
PID : 30h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 04h
- 06h
- 09h
Trigger mode (External triggering) *
Force mode (Continued power on)
Presentation mode (Auto Detection)
Level mode (Auto power off)
Alternative mode (Periodic power off)
Low Power mode (Low Power triggering)
I/O Active State
PID : 30h 01h
Size : 00h 01h (1 Byte)
- 00h
- 01h
High
Low *