Cino FA470 User Manual
Page 213

Command Descriptions
2-198
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (Continued)
Parameter / PID / Size
Options
Descriptions
Composite Code Readability
PID : 21h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
UPC Composite Mode
PID : 21h 01h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
PDF417/ Micro PDF417
Readability
PID : 22h 00h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 00h
- 01h
2
nd
Byte
- 00h
- 01h
PDF417 Readability
Disable
Enable *
Micro PDF417 Readability
Disable *
Enable
Codablock F Readability
PID : 23h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Code 16K Readability
PID : 24h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Code 16K Length
PID : 24h 01h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 01h~A0h
2
nd
Byte
- A0h~01h
Minimum Length
1~160 (Default: 1)
Maximum Length
160~1 (Default: 160)
Code 49 Readability
PID : 25h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Code 49 Length
PID : 25h 01h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 01h~51h
2
nd
Byte
- 51h~01h
Minimum Length
1~81 (Default: 1)
Maximum Length
81~1 (Default: 81)