Cino FA470 User Manual
Page 128

Command Descriptions
2-113
Parameter(s)
< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)
Parameter / PID / Size
Options
Descriptions
Operation Mode
(Tethered A Series)
PID : 70h 00h
Size : 00h 03h (3 Bytes)
- 00h 01h 01h
- 01h 01h 01h
- 02h 01h 01h
- 04h 01h 00h
- 05h 01h 01h
- 06h 01h 00h
- 07h 01h 00h
- 09h 01h 01h
- 0Dh 01h 01h
Trigger mode *
Force mode
Presentation mode
Level mode
Diagnostic mode
Alternative mode
Toggle mode
Low Power mode
Multiple mode
Hand-Held Mode Illumination
& Aiming Control
PID : 70h 01h
Size : 00h 01h (1 Byte)
Bit 0
- 0
- 1
Bit 1
- 0
- 1
Hand-Held Decode Aiming Control
Disable
Enable *
Hand-Held Illumination Control
Disable
Enable *
Hand-Free Mode Decode
Aiming Control
PID : 70h 02h
Size : 00h 01h (1 Byte)
- 02h
- 03h
Disable
Enable *
Aiming Control
PID : 70h 03h
Size : 00h 02h (2 Bytes)
- 00h 00h
- 01h 00h
- 00h 03h
Regular Aiming
Intelligent Aiming *
Delay Aiming Control
Delay Aiming Timeout
Control
PID : 70h 04h
Size : 00h 01h (1 Byte)
- 02h
- 04h
- 08h
- 0Ah
- 0Fh
- 14h
- 1Eh
- 28h
200ms
400ms *
800ms
1000ms
1500ms
2000ms
3000ms
4000ms
Presentation Background
Lighting
PID : 70h 05h
Size : 00h 02h (2 Bytes)
- 00h 00h
- 00h FFh
LEDs Off
LEDs On *
Center Alignment
PID : 70h 06h
Size : 00h 02h (2 Bytes)
1st Byte
- 00h
- 01h
2nd Byte
- 00h
- 01h
Hand-Held Mode
Disable *
Enable
Hand-Free Mode
Disable *
Enable