Cino FA470 User Manual
Page 210

Command Descriptions
2-195
Parameter(s)
< Table 8-1-1 > Set Symbology Parameter(s) Field (To be continued)
Parameter / PID / Size
Options
Descriptions
Code 25 Setting
PID : 04h 07h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 00h
- 01h
2
nd
Byte
- 00h
- 01h
Check Digit Verification
Disable *
Enable
Check Digit Transmission
Disable *
Enable
Code 25 Length
PID : 04h 08h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 01h~62h
2
nd
Byte
- 62h~01h
Minimum Length
1~98 (Default: 4)
Maximum Length
98~1 (Default: 98)
Code 11 Readability
PID : 05h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Code 11 Setting
PID : 05h 01h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 00h
- 01h
- 02h
2
nd
Byte
- 00h
- 01h
Check Digit Verification
Disable *
1-check digit verification
2-check digit verification
Check Digit Transmission
Disable *
Enable
Code 11 Length
PID : 05h 02h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 01h~62h
2
nd
Byte
- 62h~01h
Minimum Length
1~98 (Default: 4)
Maximum Length
98~1 (Default: 98)
Code 93 Readability
PID : 06h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable
Enable *
Code 93 Check Digit
Transmission
PID : 06h 01h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Code 93 Length
PID : 06h 02h
Size : 00h 02h (2 Bytes)
1
st
Byte
- 01h~62h
2
nd
Byte
- 62h~01h
Minimum Length
1~98 (Default: 1)
Maximum Length
98~1 (Default: 98)