Cino FA470 User Manual
Page 31

Command Descriptions
2-16
Reply Format
Part 1 – First Image Data Command
Prefix
Opcode
Status
Length
Parameter
CRC16
Suffix
7Eh
0Fh 1Ah 02h
34h
10h 00h
See Below
Variable
7Eh
1 Byte
3 Bytes
1 Byte
2 Bytes
4096 Bytes
2 Bytes
1 Byte
Parameter
Image Width
Image Height
Image Size
Image Data
4 Bytes
(Big Endian)
4 Bytes
(Big Endian)
4 Bytes
(Big Endian)
4084 Bytes
Part 2 – Subsequent Image Data Commands
Prefix
Opcode
Status
Length
Parameter
CRC16
Suffix
7Eh
0Fh 1Ah 02h
34h
10h 00h
<Image Data>
Variable
7Eh
1 Byte
3 Bytes
1 Byte
2 Bytes
4096 Bytes
2 Bytes
1 Byte
Part 3 – Last Image Data Command
Prefix
Opcode
Status
Length
Parameter
CRC16
Suffix
7Eh
0Fh 1Ah 02h
14h
See Note
<Image Data>
Variable
7Eh
1 Byte
3 Bytes
1 Byte
2 Bytes
Maximum 4096 Bytes
2 Bytes
1 Byte
.
Notes
1.
Status is defined as follows:
Value
Bit 2 ACK/NAK
Bit 4 Check Digit
Bit 5 Continuation
Other Bits
0
Do not request
LRC (1 Byte)
Last packet
1
Request
CRC16 (2 Bytes)
Intermediate packet
Reserved
Always 0
2.
Length of the Last Image Data Command equals to the length of the remaining Image Data
which should be no more than 4096 bytes.
3.
CRC16 Check Digit is calculated from the beginning of the Opcode field to the end of the
Parameter field.