Cino FA470 User Manual
Page 172

Command Descriptions
2-157
Parameter(s)
< Table 6-5-3 > Reply WF Operation Parameter(s) Field (To be continued)
Parameter / PID / Size
Options
Descriptions
Power Saving Timeout
PID : 00h 09h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
1 second
5 seconds *
10 seconds
20 seconds
30 seconds
Immediately
Buzzer Tone Adjust
PID : 01h 00h
Size : 00h 02h (2 Bytes)
1
st
~2
nd
Byte
- 00h 00h
- 01h 01h
- 01h 02h
- 01h 03h
- 01h 04h
Mute
Low
Medium *
High
Extremely High
Power on beep
PID : 01h 01h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Enable *
Disable
Power on Indication
PID : 01h 02h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
Disable (LED off)
LED steady on *
LED flash
Vibrator
PID : 01h 03h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
1D Barcode Inverse Reading
PID : 02h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
Dollar Sign Control
PID : 02h 01h
Size : 00h 01h (1 Byte)
- 00h
- 80h
- A2h
- A3h
- A5h
Output as “$” *
Output as “€“
Output as “¢“
Output as “£“
Output as “
¥”
Redundancy
PID : 02h 02h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
None
Level 1 *
Level 2
Level 3
Level 4
Level 5
Good Read Delay
PID : 00h 06h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
- 06h
None*
200 ms
500 ms
1 s
1.5 s
2 s
3 s
Good Read Duration
PID : 01h 04h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
Short
Medium *
Long
Extremely long
Extremely short
Good Read Indicator
PID : 01h 05h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable
Enable *