Transmit record – Cino FA470 User Manual

Page 26

Advertising
background image

Command Descriptions

2-11

Transmit Record

(WF)

Descriptions

Transmit all record(s) of Batch Mode
Available for F & L series

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

80h 11h 01h

00h

00h 00h

<Null>

90h

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

0 Byte

1 Byte

1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, the device will reply the

“Transmission Start Command” followed by the raw record data and the data transmission will end

with the “Transmission End Command”. Please refer to the following table for details. Otherwise, a

Device NAK will be sent to host to indicate a command error. However, if the host can receive any

response from the device within the user preset time-out duration, please resend the above

command.


. Parameter(s) Field

Get Device Status can request multiple parameters at one time, so it takes compound parameters.

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”


. Size

Total size (bytes) of the Options field

Reply Format

Part 1 – Transmission Start Command

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

01h 02h 00h

00h

00h 00h

<Null>

03h

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

0 Byte

1 Byte

1 Byte

Part 2 – Raw Data
Part 3 – Transmission End Command

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

01h 02h 01h

00h

00h 00h

<Null>

02h

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

0 Byte

1 Byte

1 Byte

Advertising