Command Descriptions
2-132
Reply FS Operation
(FS)
Descriptions
Reply the desired one or more parameters of the Operation Settings for Fixed Mount and Scan
Module
Reply FS Operation is sent by the device in response to the Get FS Operation command. It sends
the values for all the desired parameters requested in the Get FS Operation command.
Available for FM480, FA470, SM380 & SM5700 series
Packet Format
Prefix
Opcode
Status
Length
Parameter(s)
LRC
Suffix
7Eh
0Ah 00h 00h
00h
Variable
See Below
Variable
7Eh
1 Byte
3 Bytes
1 Byte
2 Bytes
Variable
1 Byte
1 Byte
Parameter(s)
First Parameter
………
Last Parameter
PID
Size
Options ………
PID
Size
Options
2 Bytes 2 Bytes Variable ……… 2 Bytes 2 Bytes Variable
See Next Page
. Host Requirements
Since Reply FS Operation is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Set FS Operation can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
. LRC
”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”
. Size
Total size (bytes) of the Options field