Timer/counter resolution and maximum range, Series 3100 resolution and range, Ge 188 – Echelon I/O Model Reference for Smart Transceivers and Neuron Chips User Manual

Page 198: Timer/counter, Resolution and maximum range, This mod, Ge 188 (see

Advertising
background image

188

Timer/Counter Periods and Resolution

Timer/Counter Resolution and Maximum Range

Various combinations of I/O pins can be configured as basic inputs or outputs.

The application program can optionally specify the initial values of basic outputs.
Pins configured as outputs can also be read as inputs, returning the value last

written.
The gradient behavior of the timing numbers for different Neuron Chip or Smart
Transceiver pins for some of the I/O models is due to the shift-and-mask

operation performed by the Neuron system firmware.

Series 3100 Resolution and Range

For dualslope input, edgelog input, ontime input, and period input, and infrared
input, the timer/counter returns a value (or a table of values, in the case of

edgelog input) in the range 0 to 65535, representing elapsed times from 0 up to
the maximum range given in Table 66.
For oneshot output, frequency output, and triac output, the timer/counter can be

programmed with a number in the range 0 to 65535. This number represents the
waveform ontime for oneshot output, the waveform period for frequency output,

and the control period from sync input to pulse/level output for the stretched triac

and triac output.
Table 66 gives the range and resolution for these timer/counter objects at 10 MHz

(the values scale for other clock rates; that is, for a 20 MHz device, divide the

values in the table by 2). The clock select value is specified with the clock
keyword in the declaration of the I/O object in the Neuron C application program,

and can be modified at runtime by using the io_set_clock() function.

Table 66. Series 3100 Timer/Counter Resolution and Maximum Range at 10 MHz

Dualslope, Edgelog, Ontime,
and Period Inputs; Oneshot

and Triac Outputs

Frequency Output

Clock Select

Resolution

Maximum

Range

Resolution

Maximum

Range

0 0.2

μs 13.1

ms

0.4

μs 26.2

ms

1 0.4

μs 26.2

ms

0.8

μs 52.4

ms

2 0.8

μs 52.4

ms

1.6

μs 105

ms

3 1.6

μs 105

ms

3.2

μs 210

ms

4 3.2

μs 210

ms

6.4

μs 419

ms

5 6.4

μs 419

ms

12.8

μs 839

ms

6 12.8

μs 839

ms 25.6

μs 1678

ms