The X-50 can be mounted in one of three different ways, virticall, horizontally, or wall mounted. See “Wall

Mount Template” for wall mounting in structions

For best results;

If using PSTN telephone lines the X-50 should be installed near where they enter the building,

which is called the “RJ21X”.

The X-50 should be installed in a server room or anywhere that is a computer might be placed.

It should be placed on a clean hard service or mounted on a wall.

The X-50 should be connected to all devices using Category 5, Category 5E or Category 6

cables.

The X-50 should be in a location that is easily accessible by anyone who may need to perform

maintenance on the unit.

The “TEL” port (analog telephone port) on the X-50 may be connected directly to a standard

corded, cordless telephone or FAX machine.

The X-50 should be placed on a line condition Uninterrupted Power Supply (UPS) system which

will provide line conditioning and battery back up during a power outage. To minimize the num-

ber of UPS systems needed, power all telephone endpoints using Power of the Ethernet (PoE).