Introduction

15

VCC range 2 V to 7.5 V, resolution 50 mV

VPP1, 2 & 3 range 5 V to 16 V, resolution 100 mV

Overcurrent protection on all voltage sources

Logic level 5 V to 2.7 V programmable by software

Device Operation: Read, blank check, insertion/contact
check, verify, check sum, erase chip, program, memory
protect, edit buffer, configuration, load file, save file, project
file load/save

File format: Binary, Intel HEX, Intel extended HEX,
Motorola S, HP64000ABS, TEK HEX, and straight Hex

General
Power: 100 VAC to 240 VAC, 47-63 Hz auto switch

Power consumption: 65 W

Operation temperature: 5 to 45°C (41 to 113°F)

Safety: CE & LVD certified

Weight: 8.5 kg net, 10 kg shipping weight

Using the DATAMAN-848 Software

Menus
Accessing the menus can be done in two ways:

Use the mouse and click on the menu option displayed at
the top of the screen. A pull-down menu will appear, and
you can select the option you desire by clicking on that
option.

If you do not have a mouse available, you can also use the
keyboard to access the menus. Press [F10] to activate the
main menu bar.

Advertising