RTA: Peak Curves, Freq. Detection

Peak Hold Curves

The IE-33 and IE-35 will display peak information in addition to real time information in all of the display modes,
Octave through Maximum Resolution. The peak curve is shown in violet for the Octave, 1/3 Octave and 1/6
Octave displays, and in white for the Maximum Resolution display screen, as shown in the illustration across the
page. The peak curve data represents the highest levels that have been reached across the spectrum. In addi-
tion to peak data, real time information is also displayed.

To activate the Peak Hold function and display the peak hold curve, tap the pop-up “Options” menu and select
"Peak/Hold Curve." You can toggle through the various display formats (Octave to 1/3 Octave, etc.) while the
Peak Hold function is active. However, when selecting different display formats, the peak hold information will
not be preserved from display to display. Instead, it will initialize and begin again as though it had just been acti-
vated. To turn the Peak Hold function off, select "Peak/Hold Curve"" again.

Note: If you store spectral data in

a scratch memory when the Peak Hold function is activated, real time data, not the peak curve, will be stored.

Frequency and Amplitude Detection

Several different modes of frequency and amplitude detection are provided by the IE-33 and IE-35. All of them,
including the Frequency Detect indicator, operate in all resolution settings, Octave, 1/3 Octave, 1/6 Octave,
Maximum Resolution and LF Zoom.

For real time data, a frequency detect cursor can be activated which constantly searches the spectra and dis-
plays the frequency of the highest level found in the spectrum. Real time data, or peak hold data, can also be
frozen using the "Stop" stylus button, and then be interrogated for frequency information using a provided cursor,
as demonstrated in the illustration across the page. The cursor can be moved using the stylus or the joy stick.
Additionally, any recalled and displayed memory can be interrogated for frequency information in the same
manner.

Frequency Detect: To activate the Frequency Detect mode (especially useful when searching for feedback fre-
quencies), tap the “Options” pop-up menu and select "Freq. Detect." The Frequency Detect indicator will appear
on screen and begin to search for and identify the frequency registering the highest level. To turn off the
Frequency Detect indicator, select "Freq. Detect" again.

RTA Cursor: To activate the RTA Cursor, first tap the stylus button on the bottom left labeled "Stop." This will
"freeze" the RTA display and the bar below the SPL readout will change from green to red. Next, press the left
or right joy stick. The frequency cursor (a red + in Max. Res. or a green bar in Octave, 1/3 Octave or 1/6
Octave) will appear on the curve. The cursor can be moved left or right using the left and right controls of the
joy stick, or by using the stylus to tap, and thereby select, a new position. As it moves, frequency and amplitude
will be indicated in the SPL readout window and all areas of interest can be interrogated. To turn off the RTA
Frequency Cursor, tap the "Start" stylus button to return the analyzer to its real time display.

Peak Cursor: When the "Peak Hold Curve" is being displayed, peak hold data can be interrogated using the
Peak Cursor. To accomplish this, first turn on the Peak Hold Curve by selecting it from the ”Options” pop-up
menu. Next, tap the "Stop" stylus button. When the display has been stopped, select "Peak Cursor" from the
“Options” menu. The joy stick, or stylus, can then be used to move left or right along the spectrum to interrogate
the Peak Curve for frequency and amplitude information. Selecting "Peak Curve" again turns off this function.

Memory Cursor: This function works identically to the Peak Cursor. To activate the Memory Cursor, tap a
memory stylus button to recall the memory of interest. With the memory display on the IE-33, or IE-35 screen,
tap the “Options” pop-up window and select "Memory Cursor." The Memory Cursor will appear on the curve.
The cursor can be moved left or right along the curve by using the left and right controls of the joy stick, or the
stylus.. As it moves, frequency and amplitude will be indicated. To turn off the Memory Cursor, select "Memory
Cursor" from the “Options” menu again.