B. NuTAP-S61 HyperTerminal Command – counter

Command Descriptions – counter

The counter show command allows you to view all NuTAP-S61’s counter report, as
well as hardware temperature. You can also add additional commands behind the
counter show command as listed down below:

The counter show usc [a0 | a1] [group=0 | group=1] command allows you
to view NuTAP-S61’s USC (Universal Stream Counter) report of its Network
Port (A0/A1)
and the USC group. For example, to view the USC in USC
group 0 for Network Port A0, please input the command “counter show usc
a0 group=0
”.

show

usc

configure

The counter show configure command allows you to view
USC’s settings.

clear

The counter clear command allows you to clear all counters.

show

The refreshtime show command allows you to view the refresh time for the
report.

refreshtime

set

The refreshtime set command allows you to set the refresh time (in
seconds) for the report.

The counter setusc command allows you to configure NuTAP-S61’s USC (Universal
Stream Counter) settings. Please refer to the sections down below for detailed
descriptions. Also, to view command lists for USC settings, you can input “counter
help setusc
”.

The counter setusc [a0 | a1] [group=0 | group=1] baseaddress [da
| sa | vid | mpls | dip | sip | dp | sp | vlancos | vid&vlancos]
<value>
command allows you to change the specific base address for
NuTAP-S61’s certain Network Port (A0/A1) and the USC group.
Please refer to the table down below for command initial reference:

DA: Destination Address

SA: Source Address

VID: VLAN ID

MPLS: Multi-Protocol Label
Switch

DIP: Destination IP Address

SIP: Source IP Address

DP: Destination Port

SP: Source Port

VLANCOS: VLAN Class of
Service

VID&VLANCOS: VLAN ID and
VLAN Class of Service

baseaddress

For example, to set the USC in source IP address of USC group 0 for
Network Port A0 to 192.168.1.1, please input the command “counter
setusc a0 group=0 baseaddress sip 192.168.001.001
”.

The setusc [a0 | a1] [group=0 | group=1] mode [normal | jitter]
command allows to change the mode for NuTAP-S61’s certain
Network Port (A0/A1) and the USC group. There are two modes
available here:

Normal: The USC will run
under normal mode.

Jitter: The USC will run under
jitter mode.

mode

For example, to set the mode of USC group 0 for Network Port A0 to
normal, please input the command “counter setusc a0 group=0
mode normal
”.

counter

setusc

enable/disable

The setusc [a0 | a1] [group=0 | group=1] [enable | disable]
command allows you to enable/disable NuTAP-S61’s certain Network
Port (A0/A1)
and the USC group. For example, to enable USC group
0 for Network Port A0, please input the command “counter setusc a0
group=0 enable
”.