- C 33 -

Short Seam Automat 1911-4 / 1912-4 Working Instructions

Beisler Automated Sewing Equipment

C.3

Start-up

C.3.2 Compressed air

The compressed air connection is preinstalled on the
machine. It comprises the following components:

Pressure reducer

1 with manometer 4 and water

separator

3,

Pressure hose with push-in plug

2.

The pressure reducer is mounted to the side mounting wall
of the worktable.

Connecting the machine to the compressed air sup-
ply system:
1. Connect pressure hose plug to on-site terminal unit.
2. Open on-site compressed air supply.
3. Set pressure reducer to a machine operating pressure

of 6 bar by rotating pressure reducer knob

5 and read

value on manometer

4:

• To increase pressure, rotate in clockwise direction,
• To reduce pressure, rotate in counter-clockwise di-

rection.

Setting pressures:
The operating pressures are set at the three valves:

To increase the pressure, rotate the switch in the clo-
ckwise direction.

To reduce the pressure, rotate the switch in the counter-
clockwise direction.

Function of the valves:

Pneumatic spring 6: approx 0.4 bar, controls the tra-
veling speed of the clamp to the stop.

Downholder 7: approx 0.4 bar, controls the pressure
of the roller on the clamp.

Clamp pressure 8: 0.4 - 0.5 bar, controls the pressu-
re of the clamp on the sewing material.

Fig. 3

Fig. 3