Maintenance – Beisler 1911-4 User Manual

Page 40

Advertising
background image

Short Seam Automat 1911-4 / 1912-4 Working Instructions

- C 40 -

Beisler Automated Sewing Equipment

C.5

Maintenance

C.5.4 Repairs

Clamp transport belt replacement:
1. Disconnect machine from power supply system.
2. Fig. 8: Remove retaining screws

3 from drive roller

cover

2 and remove cover.

3. Remove two retaining screws from slide roller cover

a and remove cover b.

4. Loosen two belt lock screws

5 and release belt ten-

sion

8.

5. Loosen lock nuts

7 of set screws 6 and rotate two

set screws backward.

6. Remove belt and open connector

4.

7. Fig. 7: Remove two connecting screws

1. Separa-

te upper part

2 from lower part 4 of connector.

8. Push clamp to left end position until it reaches the stop.
9. Fig. 8: Install belt over guide pulley

9 to drive roller

1 and slide roller c.

10.Fig. 7: Position connector and secure it using the

screws.

NOTE - Connector alignment!

To prevent the connector from moving over the drive or
guide rollers during clamp transport, the connector must
be positioned at a distance of exactly 60 mm from the right
end point of the clamp transport.

Fig. 8

Fig. 7/8

Fig. 7

11.

The ends of the belt

3 are fitted with holes. Install

the upper and lower part exactly over the holes of the belt
and connect the two parts and the belt using the connecting
screws.
12.Fig. 8: Tension belt by tightening two set screws

6

until the belt can be depressed approx 10 mm with di-
stinct counterpressure at the middle of the linear rail.
Tighten lock nuts

7 and lock screws 5

13. Install the two covers

2 and b.

1
2

60 mm

3

4

a

9

b

c

2

1

3 4

6

8

5

5

7 6

Advertising