Factory settings – Beisler 1911-4 User Manual

Page 86

Advertising
background image

Short Seam Automat 1911-4 / 1912-4 Working Instructions

- D 86 -

Beisler Automated Sewing Equipment

D.4

Factory settings

D.4.1

Factory settings for global parameters

M 01 global parameters 1911-4 / 1912-4:

Pos.

Global parameters 1911-4 / 1912-4

Value

Unit

01

CLAMP FWD. TO PART

0.8

sec

02

TILL CLAMP DOWN

0.3

sec

03

TILL VACUUM OFF

0.3

sec

04

THREAD LENGTH, BOBBIN FULL

004

m

05

TILL CLAMP INSERTING

0.2

sec

06

SEWING END ->CL.SIDEW

0.1

sec

07

TIME AFTER CLAMP OPEN

0.5

sec

17

TILL TENSION OPEN

0.00

sec

18

DURATION OF TENS. OPEN

0.2

sec

19

TILL THREAD CLAMP FORW.

0.5

sec

20

DUR.THREAD CLAMP FORW.

0.6

sec

29

TILL SWING RETAINER DWN.

0.0

sec

30

TILL RETAINER SWINGS

0.0

sec

31

DUR.OF PULLING RETAINER

0.0

sec

32

BLOW OUT THE PART

0.5

sec

33

CLAMP MOVES TO STACKER

0.0

sec

35

THREAD CATCH. "UP" POS

023

INC

36

SWITCH ON POS.OF TRIMM.

100

INC

37

TRIMMING SPEED

180

Upm

38

DURATION OF TRIMMING

0.35

sec

39

THREAD CATCH.TURNS BACK

25

INC

40

PROCESS IN STEPS

00

Advertising