Programming – Beisler 1911-4 User Manual

Page 84

Advertising
background image

Short Seam Automat 1911-4 / 1912-4 Working Instructions

- D 84 -

Beisler Automated Sewing Equipment

D.3

Programming

D.3.10 Level 2 special parameters / Lists

Parameter settings for level 2 submenus:
The following section describes the special parameters that
are set in lists. When a submenu is requested, only tho-
se positions of the parameter list are displayed that refer
to the machine function. All other positions of the entire
parameter list can be browsed.

Browse through the list:

Press

0 or / key.

Move to a line in the list:

Press

# or $ key.

Functions of the special parameter menu

&+2?3A



F1

Back to start level

F3

Select start modes, list

F4

Set upper part parameters, list

F5

Set stitch lengths and bar tacks, list

F6

Parameters for clamp transport, list

Selecting start modes:

Four modes can be set in this menu:

Start mode,

Blowing mode,

Holding stamp mode,

Ejector stamp mode.

Press

2 key.

Change parameters:

Press

% key.

Insert new value using numeric keypad or

Press

0 or / key.

Confirm input:

Press

% key.

Settable values:

Start mode
The selected start mode determines how the machine
operation is started and executed. Three modes are availa-
ble:

Mode 00,

Mode 01,

Mode 02.

The individual settings for machine operation are described
in Section B.3.9, Machine operation.

Blowing mode
This mode determines if the function "Blow sewing pie-
ce off" is enabled or disabled after tucking.

00, disabled,

01, enabled.

Holding stamp mode
Two modes are available for the holding stamp.
1911-4

Mode 00: The holding stamp is disabled.

Mode 01: The holding stamp is lowered after the va-
cuum switches on and the footswitch is released. When
the vacuum switches off, the holding stamp is raised

1912-4

Mode 01, the ejector stamp is lowered and travels a
quarter-circle swivel, the sewing piece is blown off ans
stacked.