Short Seam Automat 1911-4 / 1912-4 Working Instructions

Beisler Automated Sewing Equipment

C.5

Maintenance

C.5.4 Repairs

Any repairs to the machine must only be carried out by:

authorized Technical Service,

personnel that has been instructed about the setting
up and maintenance of the machine on the occasion
of a training by the supplier or manufacturer of the ma-
chine.

Use only original spare parts for installing or replacing
machine components.
Manufacturer and supplier will not be held responsible for
spare parts from third parties.

NOTE - Programming instructions!

Repairs require that machine components carry out their
individual movements and that the machine movements
are tested. These functions are controlled on level 1 of the
service menu.
For the necessary instructions, please refer to the pro-
gramming instructions.

Operating panel replacement:
1. Disconnect machine from power supply.
2. Fig. 6: Remove two lock screws

2 and disconnect

interface connector

3.

3. Remove retaining screws

1 from operating panel

bracket.

4. Remove operating panel

5, install new panel and

secure using screws.

5. Connect interface connector to receptacle

4 and se-

cure using two lock screws

2.

Fig. 6