Programming – Beisler 1911-4 User Manual

Page 82

Advertising
background image

Short Seam Automat 1911-4 / 1912-4 Working Instructions

- D 82 -

Beisler Automated Sewing Equipment

D.3

Programming

D.3.7 Level 3 special parameters / Functions

Switching photocell for beginning of seam on or
off:

If the photocell that scans the start position of the seam
is switched off, the machine control requires a fixed inser-
tion distance for machine operation. Therefore, switching
off the photocell results in a switch-over to a fixed inser-
tion length (see Fig. 5). This function is directly related to
the photocell correction functions of the service menu.

>

Press

 key.

The alternating request of this function switches between
two modes:
Photocell for beginning of seam and fixed insertion di-
stance.

Switching photocell for end of seam on or off:

If the photocell that scans the end position of the seam
is switched off, the machine control requires a fixed point
for the end of the seam to ensure correct machine ope-
ration. Therefore, switching off the photocell results in a
switch-over to a fixed end of seam point. This function is
directly related to the photocell correction functions of the
service menu.

=

Press

 key.

The alternating request of this function switches between
two modes:
Photocell for end of seam and fixed end of seam point.
This function can only be enabled if the function "se-
wing to fixed end of seam point" (level 4) is disabled.

D.3.8 Level 4 special parameters / Functions

Functions of level 4 submenus:

&D

9,



F1 Back to level 3
F2 Switch vacuum on or off
F7 Switch sewing to fixed end of seam point on or off
F8 Request next level (level 5)

Switching vacuum supply on or off:

The vacuum used to fix the sewing piece before it is trans-
ferred to the clamp transport can be switched off while
machine movements are checked. To switch the vacuum
on or off:

D

Press

 key.

NOTE - Operation without vacuum!

During normal production, the vacuum supply should al-
ways be switched on as otherwise machine operation may
be impaired.

Switching sewing to fixed end of seam point on or
off:

If this function is enabled, the sewing program is set for
a fixed end of seam point. In this case the function "pho-
tocell for end of seam" (level 3) is disabled.

9

Press

 key.