Comtech EF Data SDM-650B User Manual
Page 108

Operation
SDM-650B Satellite Modem
4–6
Rev.
5
Table 4-3. Select Monitor Menu
Menus
Submenus/Options
Comments
Raw_BER
Range: < 1.0E-4 to 2549E-4
Corr_BER
Range: > 1E-8 to > 1E-3
Eb/N0
Range: < 3.2 dB to > 9.7 dB
SWP_FREQ
Range: -25000 to +25000 Hz
Displays information when fast
acquisition has been turned ON in
the Utility menu.
RXSignal
Range: < -60 dBm to > -30 dBm
Note: Data is not available or displayed when the decoder loses lock.
Table 4-4. Select Faults Menu
Menus
Submenus/Options
Comments
Mod_Flts RF_Syn
Data Clk
TClk Syn
I-Channl
Q-Channl
AGC levl
Module
Dmd_Flts C_Detect
RF_Syn
Data_Clk
I-Channl
Q-Channl
Dscramblr
BERthrsh
Module
CEq_Flts Battery
-12 volt
+12 volt
+5 volt
Controlr
Intrface
Note: Fault conditions are displayed as a “+” on the screen.