B.1.4.2 modem faults status (summary) – Comtech EF Data SDM-650B User Manual
Page 196

Remote Control Operation
SDM-650B Satellite Modem
B–20
Rev. 6
B.1.4.1.4 Demodulator/Decoder Configuration Program
This command is used by the SMS-658 M:N protection switch to collect information that
is necessary to configure backup modems.
Command:
<add/DCP_”cr”
Response:
>add/DCP_”cr”
BBL_xxx”cr”
Baseband Loopback (ON/OFF)
IFL_xxx”cr”
IF Loopback (ON/OFF)
RFL_xxx”cr”
RF Loopback (ON/OFF)
DF_nnn.nnnn”cr”
Demodulator Frequency
DR_nnn_mmmm.m”cr”
Demodulator Data Rate
DE_xxx”cr”
Descrambler Enable (ON/OFF)
RC_xxx”cr”
Receive Clock (NRM/INV)
BERT_xxxx”cr”
BER Threshold
SR_xxx”cr”
Sweep Reacquisition (seconds)
FAM_xxx”cr”
Fast Acquisition Mode
(See Note 1)
SCF_snnnnn”cr”
Sweep Center Frequency
(See Note 1)
SWR_nnnnn”cr”
Sweep Width
(See Note 1)
SD_s”cr”
Sweep Direction
(See Note 2)
BC_xxx”cr”
Buffer Clock Source
(See Note 2)
IBS_nnnnn”cr””lf”]
Interface Buffer Size
Notes:
1. “SCF_”, “SWR_”, and “SD_” responses are returned only when fast acquisition
is enabled. See the “FAM_” command definition.
2. “BC_” and “IBS_” responses are returned only when Buffer Control is enabled.
See the “BUFF_” command definition.
B.1.4.2 Modem Faults Status (Summary)
This command returns the current overall fault conditions of the modem.
Command:
<add/MFS_”cr”
Response:
>add/MFS_”cr”
DMD_xxx”cr”
Demodulator (FLT/OK)
MOD_xxx”cr”
Modulator (FLT/OK)
CEQ_xxx”cr”
Common Equipment (FLT/OK)
(See Note)
IRX_xxx”cr””lf”]
Interface Receive Side (FLT/OK)
Note: “IRX_” response is returned only when Buffer Control is enabled. See the
“BUFF_” command definition.