B.1.4.13 Stored Faults
Information on stored faults is returned when requested. If no stored fault exists for a
given fault number, the words “NO FAULT” will be returned instead of the normal
time/date status information.
The following symbols are commonly used to define the stored faults status commands:
• “#”
Fault number (0 to 9), “0” is the first fault stored.
• hh
Hours in 24-hr. format.
• mm Minutes.
• ss
Seconds.
• MM Month.
• DD Day.
• YY Year.
B.1.4.13.1 Modulator Stored Faults
Command:
<add/MSF_#”cr”
Response:
>add/MSF_# hh:mm:ss MM/DD/YY”cr”
MOD_xxx”cr”
Module missing or will not program (OK/FLT)
AGC_xxx”cr”
AGC leveled (OK/FLT)
SYN_xxx”cr”
Carrier synthesizer (OK/FLT)
BCLK_xxx”cr”
Bit clock (OK/FLT)
TCLK_xxx”cr”
Transmit clock (OK/FLT)
ICH_xxx”cr”
I Channel (OK/FLT)
QCH_xxx”cr””lf”]
Q Channel (OK/FLT)
B.1.4.13.2 Demodulator Stored Faults
Command:
<add/DSF_#”cr”
Response:
>add/DSF_# hh:mm:ss MM/DD/YY”cr”
DMD_xxx”cr”
Demod Module (OK/FLT)
CD_xxx”cr”
Carrier Detect (OK/FLT)
SYN_xxx”cr”
Synthesizer Lock (OK/FLT)
DSCR_xxx”cr”
Descrambler (OK/FLT)
ICH_xxx”cr”
I Channel (OK/FLT)
QCH_xxx”cr”
Q Channel (OK/FLT)
BCLK_xxx”cr”
Bit Clock (OK/FLT)
BERT_xxx”cr””lf”]
BER Threshold (OK/FLT)