F.5.2.2 select monitor – Comtech EF Data SDM-650B User Manual
Page 287

SDM-650B Satellite Modem
Asynchronous Overhead Channel Unit
Rev. 5
F–29
F.5.2.2 Select Monitor
Refer to Table F-8.
When the Monitor level is entered, use
[
←
]
and
[
→
]
to select the desired monitor function.
Each monitor function is displayed in real time as long as it is selected.
Function
Description
Raw_BER
Raw bit error rate.
Range: < 1.0E-4 to 2550E-4
(See Note)
Cor_BER
Corrected bit error rate.
Range: < 1.0E-8 to > 1E-3
(See Note)
Eb/N0 Energy(bit)/noise
ratio.
Range: < 3.2 to > 9.7 dB
(See Note)
SWP Freq
Sweep monitor.
Range: -30,000 to +30,000 Hz
Fil_Stat Plesiochronous
buffer fill status in percent.
Range: 1% to 99%
(See Note)
RXSignal
Receive signal level.
Range: < -60 to -30 dBm
(See Note)
RX 2047
Receive 2047 BER.
Range: < 1.0E-3 to > 1E-6, < 1E-6, or no data
Note: When the decoder loses lock, no data is available, and is so indicated.