B.2.5 interface configuration commands, B.2.4.8.3 sweep direction, B.2.5.2 buffer clock – Comtech EF Data SDM-650B User Manual

Page 221

Advertising
background image

SDM-650B Satellite Modem

Remote Control Operation

Rev. 6

B–45

B.2.4.8.3 Sweep Direction

This command sets the direction of the sweep travel. “+” sets incremental sweep, while
“-” sets decremental sweep.

Command:

<add/SD_s”cr””lf”

Response:

>add/SD_s”cr””lf”]


Status Only: <add/SD_”cr””lf”
Response:

>add/SD_s”cr””lf”]

Where: s = + or - (direction of sweep travel during acquisition).


Note: This command is only valid when fast acquisition is enabled. See the “FAM_”
command definition.

B.2.5 Interface Configuration Commands

B.2.5.1 Transmit Clock

Command:

<add/TC_xxx”cr”

Response:

>add/TC_xxx”cr””lf”]


Status Only: <add/TC_”cr”
Response:

>add/TC_xxx”cr””lf”]

Where: xxx = INT or EXT.

B.2.5.2 Buffer Clock

Command:

<add/BC_xxx”cr”

Response:

>add/BC_xxx”cr””lf”]


Status Only: <add/BC_”cr”
Response:

>add/BC_xxx”cr””lf”]

Where: xxx = SAT, INT, EXT, or REF.


Note: Available with buffer support hardware only.

Advertising