B.1.3.18 date, B.1.3.19 clear stored faults, B.1.3.20 ber threshold – Comtech EF Data SDM-650B User Manual
Page 189
Advertising

SDM-650B Satellite Modem
Remote Control Operation
Rev. 6
B–13
B.1.3.18 Date
Command:
<add/DATE_mm/dd/yy”cr”
Response:
>add/DATE_mm/dd/yy”cr””lf”]
Status Only: <add/DATE_”cr”
Response:
>add/DATE_mm/dd/yy”cr””lf”]
Where:
mm = month.
dd = day.
yy = year.
Example: Set modem 235 date to 11/30/87.
Command:
<235/DATE_11/30/87”cr”
Response:
>235/DATE_11/30/87”cr””lf”]
B.1.3.19 Clear Stored Faults
This command is used to clear all stored faults logged by the modem.
Command:
<add/CLSF_”cr”
Response:
>add/CLSF_”cr””lf”]
B.1.3.20 BER Threshold
Command:
<add/BERT_xxxx”cr”
Response:
>add/BERT_xxxx”cr””lf”]
Status Only: <add/BERT_”cr”
Response:
>add/BERT_xxxx”cr””lf”]
Where: xxxx = NONE or 1E-n (n = 3, 4, 5, 6, 7, or 8 [exponent of threshold]).