B.2.8.5 common equipment status, B.2.8.6 interface transmit side status, B.2.8.7 interface receive side status – Comtech EF Data SDM-650B User Manual
Page 237

SDM-650B Satellite Modem
Remote Control Operation
Rev. 6
B–61
B.2.8.5 Common Equipment Status
The common equipment status command causes a block of data to be returned which
indicates the status of the common equipment.
Command:
<add/CES_”cr”
Response:
>add/CES_”cr”
M&C_xxx”cr”
Monitor and Control Module (OK/FLT)
INT_xxx”cr”
Data Interface Module (OK/FLT)
BAT_xxx”cr”
Battery (OK/FLT)
PS1_xxx”cr”
+5V Power Supply (OK/FLT)
PS2_xxx”cr”
+12V Power Supply (OK/FLT)
PS3_xxx”cr”
-12V Power Supply (OK/FLT)
MODE_xxxxxx”cr”
Mode (LOCAL or REMOTE)
SW_x.xxx”cr”
Software Version
SFLT_xx”cr””lf”]
Number of Stored Faults Logged (0 to 10)
B.2.8.6 Interface Transmit Side Status
Command:
<add/ITXS_”cr”
Response:
>add/ITXS_”cr”
CLK_xxx”cr”
Selected Transmit Clock Activity
(OK/FLT)
PLL_xxx”cr”
Transmit Synthesizer PLL Lock
(OK/FLT)
SFLT_xx”cr””lf”]
Number of Stored Faults Logged (0 to 10)
B.2.8.7 Interface Receive Side Status
Command:
<add/IRXS_”cr”
Response:
>add/IRXS_”cr”
MUX_xxx”cr”
MUX Lock (OK/FLT)
CLK_xxx”cr”
Selected Buffer Clock Activity
(OK/FLT)
PLL_xxx”cr”
Receive Synthesizer PLL Lock
(OK/FLT)
(See Note)
OVFL_xxx”cr”
Buffer Overflow (OK/FLT)
(See Note)
UNFL_xxx”cr”
Buffer Underflow (OK/FLT)
(See Note)
IBFS_nn%”cr”
Interface Buffer Fill Status
SFLT_xx”cr””lf”]
Number of Stored Faults Logged (0 to 10)
Note: Available with buffer support hardware only.