Limitorque actuation systems, Flow control division, Front view rear view top view – Flowserve DDC-100 Master Station II User Manual

Page 86: Front view

Advertising
background image

86

DDC-100 Master Station II Installation and Operation Manual

FCD LMAIM5001-00

Figure A-2: Typical hot standby Master Station II network diagram

Limito

rq

u

e Act

ua

tio

n

S

ys

tem

s

R

REVI

S

ION

RACK MOUNT

ABLE HOT

S

TA

N

D

B

Y

M

A

S

TER

S

TAT

IO

N

TITLE

DRA

W

IN

G NO.

1

S

T

OR

DER

NO.

APP

ROVE

D

CHE

CKE

D

DRA

WN

DA

TE

DE

S

CR

IP

TI

O

N

NO.

REV

S

HEET

OF

DA

TE

DA

TE

DA

TE

15-493

-0384-4

1 1

DKA

9/12

/03

L-783 REV

-A 4/26/

93

MOV

-3

S

EE NOTE

5

A1* 15

A1 16

29 A2*

41 A2

MOV

-2

S

EE NOTE

5

A1* 15

A1 16

29 A2*

41 A2

MOV

-1

S

EE NOTE 5

A1* 15

A1 16

29 A2*

41 A2

MOV

-248

S

EE NOTE

5

A1* 15

A1 16

29 A2*

41 A2

MOV

-249

S

EE NOTE

5

A1* 15

A1 16

29 A2*

41 A2

MOV

-250

S

EE NOTE 5

A1* 15

A1 16

29 A2*

41 A2

MOV

-4

S

EE NOTE

5

A1* 15

A1 16

29 A2*

41 A2

MOV

-247

S

EE NOTE

5

A1* 15

A1 16

29 A2*

41 A2

N/C

N/C

N/C

-----

N/C

N/C

N/C

N/C

N/C

N/C

30

30

30

30

30

30

30

30

FRONT VIEW

REAR VIEW

TOP VIEW

ON/OFF

S

WITCH

110V

A

C POWER ENTR

Y

FU

S

E P

R

O

T

EC

T

IO

N

EXT

. 24VDC

MONI

TOR

FRONT VIEW

5.75

0

(146)

8.71

8

(221)

17.

0

00

(432)

19.

0

00

(483)

4X .

278

x .4

06 OBLONG

(7) (10)

17.

727

(450)

1.43

2

(36)

TERMINAL

S

& CONNECTOR

S

HANDLE

S

o

l

FUS

ES

FUS

ES

l

o

ETHERNET

DO NOT U

S

E

S

INGLE

--
+

24VD

C

PROPER OPERA

TION

IN

S

IDE OF UNIT

FOR

INPUT ONL

Y

EXTER

NAL 24VDC

MOV

E

JUMPER

S

ON

250 V

INPUT

POWER

~1.5A

100-240

V

AC

ON

OFF

FU

S

E

S

2 AMP

DC

S

DA

TA

*

GND

CHANNEL B

PRINTE

R / DEBUG

WITH 110-240

V

A

C

OPTIONAL

DO NOT U

S

E

HOT

S

TANDBY

GND

DA

TA *

DA

TA

DC

S

PRINTE

R / DEBUG

ON

OFF

~1.5A

INPUT

100-240

V

AC

250 V

POWER

2 AMP

FU

S

E

S

--
+

24VDC

PROPER OPERA

T

ION

IN

S

IDE OF UNIT

FOR

INPUT ONL

Y

EXTER

NAL 24VDC

MOVE JU

MPER

S

ON

WITH 110-240

V

A

C

CHANNEL A

DA

TA

NO

S

ERVICEABLE P

A

R

T

S

IN

S

IDE

MONI

TOR

GND (

S

EE NOTE 6)

MA

S

TER

S

TA

TION POWER REQUIREME

NT

S

:

S

INGLE: 110/240 V

AC, 3.

0 AMP (1.5 AMP PER CPU)

24 VDC, 4 AMP (2 AMP P

E

R CPU)

JUMPER

S

ELECT

A

BLE

(DO NOT U

S

E WITH 110-240 V

A

C CONNECTED)

TEMPER

TURE RA

TING:

S

TORAGE: -

20°C TO +60°C

OPERA

TIONAL: 0°C TO +45°C

PRINTER/DEBUG

S

AME A

S

DC

S

POR

T

R

S

-232

DC

S

POR

T

R

S

-232

DCD

RXD

TXD

DTR

GND

D

S

R

RT

S

CT

S

PIN

1

2

3

4

5

6

7

8

9

R

S

-422

R

S

-485

TXD+

RXD+

GND

RXD-

TXD-

TXRXD+

GND

TXRXD-

ETHERNET POR

T

MA

S

TER

S

TA

TION TO PC

S

TRAIGHT

-THRU

MA

S

TER

S

TA

TION TO HUB

S

TRAIGHT

-THRU

MA

S

TER

S

TA

TION TO PLC

S

TRAIGHT

-THRU

CABLE TYPE: DA

TA QUALITY CA

TEGOR

Y 5 WITH

S

TANDARD RJ-45 CONNECTOR.

JUMPER CABLE MU

S

T BE IN

S

TALLED FROM MX-DDC TERMINAL BLOCK

(6) MA

S

TER

S

TA

TION MU

S

T BE C

ONNECTE

D TO CLEAN EAR

TH-GROUND

(LE

SS

THAN 5 OHM

S

) FOR ENHANCED NOI

S

E REJECTION AND A

CLEAR/

S

AFE P

A

TH FOR

S

URGE CURRENT

S

.

POLARITY AND LEVEL OF THE NETWORK'

S

DA

T

A CONNECTION

CAN BE CHECKED

BY MEA

S

URING

VOL

T

AGE BETWEEN

DA

TA AND

DA

T

A* TERMINAL

S

. THI

S

VOL

T

AGE

S

HOULD BE GREA

TER THAN

+200mV DC WITH MA

S

TER

S

TA

TION NETWORK POR

T

S

DI

S

CONNECTED.

DA

T

A TERMINAL I

S

PO

S

ITIVE WITH RE

S

PECT TO DA

T

A* TERMI

NAL.

DA

T

A

TERMINAL I

S

PO

S

ITIV

E WITH RE

S

PECT TO DA

T

A* TERMINA

L

ACTUA

TOR, CONT

ACT ENGINEERING FOR AL

TERNA

T

IVE EAR

TH GR

OUND

IF LOW IMPEDANCE EAR

TH GROUND I

S

NOT A

V

AILABLE A

T EACH

NOI

S

E REJECTION AND PROVIDE

S

A CLEAR/

S

AFE

P

A

TH FOR

S

URGE

A CLEAN EAR

T

H-GROUND CONNE

CTION (LE

SS

THAN 5 OH

M

S

) ENH

ANCE

S

(5) EAR

TH GROUND: GROUND ROD OR CONNE

CTION TO GROUND ROD.

(4) BELDEN 3105A, 9841, OR 3074F

S

HIELDED TWI

S

TED P

AIR CABLE I

S

(3) CONNECTION

S

S

HOWN ARE TYPICAL. THE NUMB

ER OF MOV'

S

S

HOWN

(2) CORRECT POLARITY FOR FIELD UNIT AND MA

S

TER

S

T

A

TION CONNECTION

S

(1) MA

S

TER

S

T

A

TION AND FIELD UNIT

S

REQUIRE EXTERNAL POWER

S

UPPL

Y

.

PIN 30 TO EAR

TH-GROUND.

DIAGNO

S

TIC NOTE:

---------------

-

S

HIELD

30 -

S

URGE PRO

TECTION

N/C - NO CONNECTION

16 - DA

T

A A1

15 - DA

T

A A1*

41 - DA

T

A A2

29 - DA

T

A A2*

------------------

EAR

T

H GR

OUND NOTE:

S

URGE PROTECTION

S

TRA

T

EGIE

S

.

CURRENT

S

.

RECOMMENDED.

MA

Y NOT IN

DICA

TE TRUE

S

Y

S

TEM

S

IZE.

I

S

NECE

SS

AR

Y FOR PROPER

OPERA

TION.

MOV - MOTOR OPERA

TED V

AL

VE

_______LEGEND:

_____NOTE

S

:

Flow Control Division

Limitorque Actuation Systems

Advertising