Limitorque MX Electronic Actuator FCD LMENIM2306-06 – 10/13

flowserve.com

Applicable Emissions standards

EN61000-6-4:2007+A1:2011

Industrial Environments - Class A - Test Limits & Levels

Radiated emissions

EN55011:2009+A1:2010 (CISPR11)

330 MHz to 230 MHz
230 MHz to 1 GHz

40 dB (μV/m)
47 dB (μV/m)

FCC Part 15, (CFR47 Part 15.109

30 MHz to 88 MHz
88 MHz to 216 MHz
216 MHz to 960 MHz
> 960 MHz

90 dB (μV/m)
150 dB (μV/m)
210 dB (μV/m)
300 dB (μV/m)

Conducted emissions

EN55011:2009+A1:2010 (CISPR11)

150 kHz to 500 kHz
500 kHz to 30 MHz

79 dB (μV) (quasi-pk), 66 dB (μV) (avg)
73 dB (μV) (quasi-pk), 60 dB (μV) (avg)

FCC Part 15, (CFR47 Part 15.107)

Applicable immunity standards

EN61000-6-2:2005 (Perf. Criteron)

Industrial Environments - Test Limits & Levels

ESD

IEC61000-4-2 (B)

Air: AC, DC, Signal
Contact: AC, DC, Signal

±2 kV, ±4 kV, ±8 kV
±1 kV, ±2 kV, ±4 kV

Radiated RF immunity

IEC61000-4-3 (A)

Enclosure @ 80 MHz to 1 GHz

10 Vrms/m @ 80% AM, 1 kHz

Enclosure @ 1 GHz to 2.7 GHz

3 Vrms/m @ 80% AM, 1 kHz

Fast transients/burst

IEC61000-4-4 (B)

AC, Signal

±2 kV, ±1 kV

Voltage surges

IEC61000-4-5 (B)

Common: AC, Signal
Differential: AC, Signal

±2 kV, ±l kV
±l kV, ±l kV

Conducted RF immunity

IEC61000-4-6 (A)

AC @ 150 kHz to 80 MHz

10 Vrms @ 80% AM, 1 kHz

Magnetic field immunity

IEC61000-4-8 (A)

Three mounting axis

30A/m

Voltage dips and interrupts

IEC61000-4-11 (B)

3 dips, 10 sec apart

> 95% dip for 1 cycle @ 50/60 Hz
30% dip for 500 ms @ 50/60 Hz
60% dip for 200 ms @ 50/60 Hz

IEC61000-4-11 (C)

3 dips, 10 sec apart

> 95% interrupt for 5 sec @ 50/60 Hz

Table 7.1 – EMC – Electromagnetic Compatibility (EMC) and Electromagnetic Interference (EMI) standards to which this