Limitorque MX Electronic Actuator FCD LMENIM2306-06 – 10/13

flowserve.com

6

Maintenance

Under normal operating conditions, the MX is a maintenance-free actuator. For ordinary applications, the actuator will
require no formal maintenance program. However, if the actuator is used under severe service conditions or operated in
a Hazardous Location, the following maintenance procedures are required:

1. Check the oil level every 50 hours of operation at a minimum. Where conditions are severe due to frequent opera-

tion or high ambient temperatures, a more regular inspection interval should be maintained.

2. Change the gear oil every 100 hours of operation. See Section 6.1: Lubrication.

3. All ball bearings, oil seals, O-rings and quad-rings are to be replaced after 450 hours of operation. See Bulletin

LMENIM2314, MX Maintenance and Spare Parts for disassembly procedures.

Clean and lubricate the valve stem regularly to avoid torque build-up and wear due to silting and corrosion. Infrequent
operation can lead to corrosion and contamination of the valve stem thread lubricant. Check any thrust bearings that
are fitted to the actuator for proper lubrication at regular intervals. For additional details refer to LMENIM2314, MX
Maintenance and Spare Parts.

6.1 Lubrication

MX actuators are oil-filled, as standard, using Mobil SHC 632. Exxon Teresstic SHP 320 may be used as a direct
substitute. These products are synthetic machine oils suitable for ambient temperatures of -20°F to 250°F (-30°C to
120°C). For extreme low temperature conditions (< -30°C to 60°C), an alternative lubricant is available—Petro Canada
TRAXON Synthetic 75W-90 with TOS. Consult factory for arctic temperature applications.

6.1.1 Oil Capacities

To avoid pressurization of the gearcase, the following recommended oil capacities should not be exceeded:

• MX-05 – 10 oz. (256 ml)

MX-85 – 192 oz. (5.7 liters)

• MX-10 – 21 oz. (.6 liters)

MX-140 – 192 oz. (5.7 liters)

• MX-20 – 48 oz. (1.4 liters)

MX-150 – 192 oz. (5.7 liters)

• MX-40 – 65 oz. (1.9 liters))

6.1.2 Checking Oil Level

To check the level:

1. Remove the uppermost filler plug on the gearcase.

2. Check that the level of oil is within 1 inch (25 mm) of the hole (when actuator is mounted with base horizontal).