2 type “a” bases: thrust-only applications – Flowserve MX Electronic Actuator User Manual

Page 17

Advertising
background image

17

Limitorque MX Electronic Actuator FCD LMENIM2306-06 – 10/13

flowserve.com

Disassembly
No disassembly is required since the torque nut has been machined to an international standard. Clean the bore and
lightly grease.

Figure 3.4 – B1 base

NOTE: Fill base with a Lithium based EP0 grease.

Figure 3.5 – Exploded view of B1 base

Housing,

torque/thrust

Pipe plug

Washer (M4)

Socket head

cap screw (M4 x 8)

Socket head set screw

Retainer, bearing

Pilot, torque/thrust

Bearing

Torque nut (B1)

Socket head cap

screw (M8 x 20)

Pipe plug

MX-05 B1

MX-40 B1

Thrust nut

assembly

3.1.2 Type “A” Bases: Thrust-only Applications

Standard A1/A1E Base
The standard MX actuator thrust base is the A1, and may be bolted directly to the actuator. The thrust base contains a
bronze alloy thrust nut that may be machined to suit the valve stem.

An A1E (extended) thrust nut can be provided and may be installed to reach shorter stems.

Figure 3.6 – A1 base

Disassembly – Units MX-05/10/20/40
Refer to Figure 3.7.

Disassembly of the main housing from the base may be recommended to allow the base to remain on the valve if the
actuator must be removed for service.

Advertising