Limitorque MX Electronic Actuator FCD LMENIM2306-06 – 10/13

flowserve.com

3. Depress the declutch lever, and at the same time slowly rotate the handwheel until the clutch is fully

engaged. Release the lever; the clutch will be retained in the handwheel mode by spring-loaded latches.

4. Ensure the valve is fully open, then move the valve in the close direction for one handwheel turn to allow

for coasting of the motor.

5. When the valve is in the desired position, select “YES” again. The LCD will read “SAVE OPEN LIMIT OK?”

6. Select “YES” if the valve’s open position limit is correct. The open position limit is set.

7. Move the valve in the close direction. The open lamp should extinguish within one turn of the handwheel.

8. Move the valve back in the open direction and check that the open lamp illuminates just before the full open

position is reached (approximately 1/2 to 1 turn).

9. If the calibration requires adjustment, select “NO” at the “SET CLOSE POSITION LIMIT?” prompt and

repeat the “SET OPEN POSITION LIMIT?” routine.

10. Select “NO” to exit “POSITION SETUP?” or “YES” to return to “SET CLOSE POSITION LIMIT?”

a

CAUTION: On some valves, position limits could be set adjacent to each other, so be careful that the Close and
Open limits are set sufficiently apart to permit operation. If the limits are set adjacent to each other, an error
message will be displayed: “KEEP OPEN(CLOSE) LIMIT?”

NO FURTHER MOVEMENT IS PERMITTED UNTIL THE ERROR IS CORRECTED.

Should the User elect to proceed with the setting, an error will be displayed on the screen after re-booting
stating “IDENTICAL LIMITS”. THE ACTUATOR WILL NOT MOVE UNTIL THE ERROR IS CORRECTED.

Figure 2.2 – Handwheel operation

Declutch actuator;

Rotate handwheel to

CLOS E ” position limit

Rotate handwheel to

OPEN ” position limit

Enter “SETUP” mode

OPEN VALVE

OK ?

SAVE OPEN

LIMIT OK?

SETUP?

SAVE CLOS E

LIMIT OK?

CLOSE VALVE

OK ?

SET CLOS E

POSITION LIMIT?

SET OPEN

POSITION LIMIT?

EXIT

SETUP?

100%

STATUS OK

YE S

STO P

YE S

YE S

YE S

YE S

YE S

YES

YES

NO

NO

NO

NO

NO

NO

NO

NO

SET POSITION

PRECISION?

POSITION

XXX% OPEN

YES

NO

NO