Ready indicator lit, error indicator flashing, charge level indicator 1-4 flashing:

Cause:

Timeout in the corresponding charging phase or battery capacity too high

Cause:

Battery faulty (cell short circuit, heavy sulphation)

Remedy:

Check battery and replace if necessary