Technical data – Fronius Acctiva Seller User Manual

Page 52

Advertising
background image

50

Technical data

Electrical data in-
put 230 V

Standards 230V

Electrical data in-
put 120 V

Standards 120V

Mains voltage

~ 230 V AC ±15%

Mains frequency

50/60 Hz

Mains current

max. 2.9 A eff.

Mains fuse

max. 16 A

Efficiency

max. 95%

Effective power

max. 420 W

No-load power consumption

max. 1.7 W

Protection class (with ground conductor)

I

Maximum permitted mains impedance at the interface
(PCC) to the public grid

none

Mark of conformity

CE

EMC device class

A

IEC 60068-2-6

Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; acceleration 5 g)

IEC 60068-2-29

Repetitive shock (25 g / 6 ms / 1000 shocks)

EN 60335-1

EN 60335-2-29

EN 61000-3-2
EN 61000-6-2

(EN 61000-4-2, EN 61000-4-3, EN 61000-4-4)
(EN 61000-4-5, EN 61000-4-6, EN 61000-4-11)

EN 61000-6-4

(Class A)

Mains voltage

~ 120 V AC ±15%

Mains frequency

50/60 Hz

Mains current

max. 7.3 A eff.

Mains fuse

max. 20 A

Efficiency

max. 93%

Effective power

max. 420 W

No-load power consumption

max. 6.9 W

Protection class (with ground conductor)

I

Maximum permitted mains impedance at the interface
(PCC) to the public grid

none

Mark of conformity

cTÜVus

EMC device class

A

UL1236
C22.2 No 107.1-01
FCC CFR 47 Part 15

(Class A)

Advertising