Hypertherm Shape Cutting Control User Manual
Page 25

MicroEdge
19
8
Output 4 +
Hold Ignition ( Relay Contact )
9
Output 4 –
Hold Ignition ( Relay Contact )
Ground
Stud
Shield
Mating Connector
Connector AMP #206708-1
Backshell AMP #206966-1
Sockets (20-24 ga) AMP #66105-3
Cabling: Use Belden # 9504 or equivalent
Joystick
Pin # Designation
Description
1
Input
1
Joystick
UP
2
Input
2
Joystick
DWN
3
Input
3
Joystick
LT
4
Input
4
Joystick
RT
5
Common
Common
6
Analog Input 3 +
Speed Pot 1
7
Analog Input 3 –
Speed Pot 1
8
Analog Input 4 +
Speed Pot 2
9
Analog Input 4 –
Speed Pot 2
Ground
Stud
Shield
Note: Joystick inputs are activated by passing the Common signal ( pin 5 ) to the
desired input.
Analog inputs for the speedpots are rated at 0 - +10VDC
Mating Connector
Connector AMP #206708-1
Backshell AMP #206966-1
Sockets (20-24 ga) AMP #66105-3
Cabling: Use Belden # 9504 or equivalent
THC and Joystick Cable Grounding
Cable shields should be tied to the external PE studs for optimum noise
immunity.