Hypertherm Shape Cutting Control User Manual

Page 35

Advertising
background image

Edge Ti

29

Note: The input logic for the first twelve I/O would need to be inverted for Dry
Contact Mode Inputs so that logic state is shown correctly for operational mode.
An Inputs Inverted parameter has been provided for this purpose.

Front Panel I/O
Edge TI has dedicated I/O for operation of front panel switches. NOTE: For
proper operation, these inputs should not be reassigned.

Input #

Description

24

Front Panel Start

25

Front Panel Stop

26

Front Panel Forward on Path

27

Front Panel Forward on Path

28

Raise Torch 1

29

Lower Torch 1

30

Front Panel Manual

31

Front Panel E-Stop

Lifter Interface

Edge Ti offers the option of an integrated Torch Height Control. The lifter
interface connector is provided for this use. Lower Limit, Upper Limit and
Breakaway inputs are sinking inputs to Field Common. Please refer to Sensor™
PHC manual for additional information.

Lifter Pinout (9 Pin Dsub)

Pin# Description
1 Field

+12VDC

2

Lower Limit (shared w/ general input 11)

3

Upper Limit (shared w/ general input 12)

4

Breakaway (Torch Collision)

5 Field

Common

6 Field

Common

7

Plate Contact -12Vdc

8

Plate Contact Sense

9

Plate Contact Common


Shared Inputs
Note that general inputs #11 and #12 are shared with the Lifter Interface Limit
Switch inputs. These inputs can only be used as general purpose inputs if they
are NOT used by the Lifter limit switches.

If you are using the Lifter Interface and limit switches are connected to these
inputs you must, close DIP switches SW1-1 and SW1-2 and you should not
connect to inputs #11 and #12. Note that the standard Hypertherm Lifter does not