Hypertherm Shape Cutting Control User Manual
Page 40
Advertising
![background image](/files/789567/content/doc040.png)
Edge Ti
34
Additional Notes:
1. Only 5 Volt encoders are supported.
2. Hall Sensors are used with Brushless motors only.
3. Inside the Edge Ti, dipswitches are used to select Brush or Brushless
mode, 2 switches per axis. Can mix Brushed and Brushless if switches are
set properly.
4. For optimum noise immunity, cable shields may be tied externally to the
control enclosure.
Encoder Mating Connector
Connector AMP #206044-1
Backshell AMP #206070-1
Pins (20-14AWG) AMP #66103-3
Cabling: Use Belden # 9504 or equivalent for brushed motor signals
Cabling: Use Belden # 9507 or equivalent for brushless motor signals
Reminder: Drive Type selection on Axes Setup screen must be set to
CURRENT mode.
Advertising