The Mariner Shape Cutting Control is designed with all machine interface
connections passing through the pedestal mount at the base of the enclosure.
Motion and I/O are supported via the fiber optic communication ring of the
SERCOS Interface.
The information contained in this section is intended to provide the basic
information for connection of the Mariner Shape Cutting Control to the cutting
table. Each machine interface will vary slightly based on the cutting table
configuration and features.
AC Input Pinout
TB connector
Description
101
110VAC or 220VAC Input (Hot)
102
110VAC or 220VAC Input (Neutral)
AC
Power
Ground
Recommended Wire
14 AWG or greater
E-Stop
The E-stop Switch provides normally open contacts rated at 20VAC/500mA
minimum to 250VAC/6A maximum.
TB connector Description
103 Contact
Closure
104 Contact
Closure
Diagram Location Din-02