Hypertherm Shape Cutting Control User Manual

Page 37

Advertising
background image

Edge Ti

31

Mating Connector
Use Hypertherm cable CABL-0208 or recommended 15 Pin Dsub (or equivalent).

Connector AMP #205206-1
Backshell Northern Technology #C88000207
Pins AMP #1-66506-0
Cabling: Use Belden # 9541

External Interlock

An external interlock is provided to remotely disable servo power.

Interlock Pinout
Pin#
Description
1

Interlock Relay Coil (24VDC)

2 GND
3 GND
4

+24VDC (50 milliamps maximum)


Additional Notes:

1. For Servo Drive Amplifiers to operate, Pin 1 must be connected to GND

Pin 2, typically through a remote mushroom type switch. If no remote
switch is to be used, connect pin 1 to pin 2 with a jumper or the servo
drives will not power on.

2. 24VDC is provided for use to activate the digital inputs only in the case

where sourced inputs are selected, it must not be used for any other
auxiliary purpose.


Mating Connector
Connector AMP #206060-1
Backshell AMP #206062-3
Sockets 20-24AWG AMP #66105-3

Motor Encoder Connections
Edge Ti supports DC brush and brushless motors. Switch SW1 on the drive
interface can be used to select motor type being used. Please note the location
and setting in the following illustration.

Drive Type selection on Axes Setup screen must be set to CURRENT mode.