Edge Ti

28

Shared Inputs
Note that general inputs #11 and #12 are shared with the Lifter Interface Limit
Switch inputs. These inputs can only be used as general purpose inputs if they
are NOT used by the Lifter limit switches.

If you are using the Lifter Interface and limit switches are connected to these
inputs you must set DIP switches SW1-1 and SW1-2 to ON and you should not
connect to inputs #11 and #12. Note that the standard Hypertherm Lifter does not
use limit switches and the DIP switches SW1-1 & SW1-2 should be OFF so that
inputs #11 and #12 can be used.

Switch SW1-1 and SW1-2


I/O Mating Connector
The I/O connector is a standard sex circular CPC connector from AMP
Connector AMP 16C #206037-1
Backshell AMP #206070-1
Sockets 20-24AWG AMP #66105-3

I/O Setup Screen
The I/O setup screen is used to define inputs, outputs and their logic state.