Hypertherm Shape Cutting Control User Manual

Page 60

Advertising
background image

Voyager III

54

Flash Write Jumpers:
Location SW4
1 = ON, 2 = ON
Reset Button:
SW5 – Press to reset card

Error Codes:
E1 Display Code = "Voltage or Temperature Error Detected!"
Displayed if voltage or temperature sensors on Field Interface board indicate an
error. Please check power supply, wiring and connections.

E2 Display Code = "Bad Checksum for SMCC Software!"
Displayed if checksum for SERCOS Slave Flash Program is not correct.
Program needs to be reloaded using the Serial Port connection.

E3 Display Code = "Wrong Interface Board Detected for Selected SERCOS
Address!"
Displayed if the selected SERCOS Slave Address/SERCOS Slave mode does
not match the Field Interface functionality. For example, using an HPR Field
Interface with a SERCOS Slave card set to Drive Address 1-12 is not possible,
since these are axes SERCOS addresses only, not peripheral I/O SERCOS
addresses.


Advertising