MAX200

Service Manual

3-15

8-99

MAINTENANCE

6. Measure voltage at power distribution board PCB6 (Figure 3-1, item 1). Look on the board for fuses F1 through

F4 (Figure 3-2). Measurements between each fuse and chassis ground should be as follows:

F1:

24VAC

F2:

120VAC

F3:

240VAC

F4:

120VAC

If voltages are not present, or incorrect at 1 or more of these points, disconnect power and troubleshoot PCB6
fuses and associated pins, connectors and wiring between power distribution board connector REC1 and
transformer secondary T1 (Figure 3-1, item 6).

Also, check main power fuses F1 and F2 (Figure 3-1, item 3) and associated wiring and connections between
T1 and L1 and L2.

Repair or replace any defective components.

Figure 3-2

Power Distribution PCB6