Ivoclar Vivadent IPS e.max CAD Abutment Solutions User Manual
Page 30

30
IPS e.max CAD Crystall./Glaze Paste is extruded from the syringe and mixed.
If required, the paste can be thinned with IPS e.max CADCrystall./Glaze Liquid.
Important: The glazing material must reach neither the bonding surface to the Ti base
nor the screw channel, as this may compromise the accuracy of fit.
Individual characterizations of the emergence profile are applied using IPS e.max CAD
Crystall./Shades.
IPS e.max CAD Crystall./Glaze Paste is applied evenly on the emergence profile of the
hybrid abutment or the outer surface of the hybrid abutment crown.
Important: The materials must not be applied to the bonding surface to the crown,
as this might compromise the fit of the crown.
Enhancing the chroma on the buccal surface with IPS e.max CAD Crystall./Shades