Careful preparation of the bonding surface is a prerequisite for the successful adhesive cementation of the base and the
ceramic structure. The following paragraphs outline the required procedure. The procedure is the same for hybrid
abutments and hybrid abutment crowns.

Required materials
– IPS Ceramic Etching Gel
– Monobond

®

Plus

– Multilink

®

Hybrid Abutment

– Glyceringel (z.B. Liquid Strip)

IPS e.max CAD ceramic structure

(LS

2

)

Base

Blasting

According to the instructions of the

manufacturer

Etching

Bonding area to the base

with IPS

®

Ceramic Etching Gel for 20 s

Conditioning

The bonding area

with Monobond

®

Plus for 60 s

Adhesive cementation

Multilink

®

Hybrid Abutment

Covering the cementation joint

Glycerine gel, e.g. Liquid Strip

Curing

7 minutes auto-polymerization

Polishing the cementation joint

Conventional polishers for ceramic/composite resin

Preparation of the Ti base

The following procedure should be observed in the preparation of the Ti base for the cementation with the ceramic
structure:
– The Ti base should be prepared according to the instructions of the manufacturer.
– Clean the Ti base with an ultrasonic bath or with a steam cleaner and then dry it with blown air.
– Screw the Ti base on the model analog.
– Place the ceramic structure on the Ti base and mark the relative position of the components with a waterproof pen. This

facilitates locating the correct position when the parts are assembled at a later stage.

– The emergence profile of the base must not be blasted or modified in any way.
If the manufacturer recommends that the bonding surface of the Ti base be blasted, the following procedure

should be observed:

– Apply silicone (Virtual Extra Light Body Fast Set) to protect the emergence profile and the screw channel .
– Carefully blast the bonding area according to the instructions of the manufacturer.
– Remove silicone.
– Clean the Ti base with ultrasound in a water bath or with the steam jet.
– After cleaning, the bonding surface must not be contaminated under any circumstances, as this would impair the

bond.

– Apply Monobond Plus on the clean bonding surface and allow it to react for 60 s. After the reaction time, disperse any

residue with air that is free of water and oil.

– Seal the screw channel with a foam pellet or wax. The bonding surface must not be contaminated in the process.