Optional – Ivoclar Vivadent IPS e.max CAD Abutment Solutions User Manual

Page 31

Advertising
background image

31

IPS e.max CAD Crystall./Shade Incisal is applied to imitate the incisal area.

The ceramic structure is placed in the centre of the IPS e.max CAD Crystallization Tray.

The Combination firing is conducted using the stipulated firing parameters. The

firing parameters for IPS e.max CAD MO and IPS e.max CAD LT must be observed.

Optional

: For minor shape adjustments (e.g. proximal contact points), IPS e.max CAD

Crystall./Add-On is available.

The ceramic structure is removed from the furnace after completion of the firing cycle

(wait for the acoustic signal of the furnace).

Optional

Corrective firing

If characterizations or adjustments are required after crystallization, a corrective firing using
IPS e.max CAD Crystall./Shades and Stains and Glaze can be conducted. Conduct the corrective
firing also on the IPS e.max CAD Crystallization Tray.
For minor shape adjustments (e.g. proximal or occlusal contact points), IPS e.max CAD Crystall./Add-On is available.
The detailed procedure is described on page 33.

Completing the IPS e.max CAD Ceramic Structure

– Staining T

echnique on the Blue Restoration

Once the IPS e.max CAD ceramic structure has cooled to room temperature, proceed with the following steps:
– Remove the ceramic structure from the IPS e.max CAD Crystallization Pin XS.
– Remove any residue with ultrasound in a water bath and/or with the steam jet.
– Do not remove residue with Al

2

O

3

or glass polishing beads.

– Place the ceramic structure on the Ti base and check the fit.
If adjustments by grinding are required, make sure that no overheating of the ceramic occurs.