47
Application Procedure
– Permanent Cementation
The Ti base is screwed on the model analog. The relative position to the ceramic
structure is marked with a waterproof pen.
The bonding surface can be carefully blasted according to the instructions of the
manufacturer.
E.g. silicone (Virtual Extra Light Body Fast Set) is applied in order to protect the
emergence profile and the screw channel.
Removal of the silicone and subsequently cleaning with ultrasound in a water bath
or with the steam jet.
Monobond Plus is applied to the clean bonding surface and allowed to react for
60 s. After the reaction time, any remaining residue is dried with blown air that is
free of water and oil.
The screw channel is sealed with a foam pellet or wax.
The bonding surface must not be contaminated in the process.