Figure 4: optional dc power cable, Table 3: optional dc pwr cable pin assignments – NavCom RT-3020 Rev.F User Manual

Page 33

Advertising
background image

RT-3020 User Guide – Rev. F

P/N 94-310060-3010 is an optional 10ft (3m)
unterminated power cable fitted with a LEMO plug
type (Mfr. P/N FGG.1K.304.CLAC50Z), with red strain
relief. The wiring color code and pin assignments are
labeled on the cable assembly and provided in
Table 3 below.

Table 3: Optional DC Power Cable Pin Assignments

Color Signal Pin

No

Black 1

Brown

Return

2

Red 3

Orange

Power

4

Figure 4: Optional DC Power Cable

The GPS sensor is protected from reverse polarity
with an inline diode. It will operate on any DC voltage
between 10 and 30VDC, 5 watts (maximum).

‡

Voltages less than 10VDC will turn the
unit off. To turn the unit on, power
must be in the 10 to 30VDC range.
Press and hold the I/O switch in for
more than 3 seconds.

To set the receiver to power up as
soon as power is applied to the DC
Input port, refer to the StarUtil Users
Guide
, Power Management or the

2-31