Description of Components

Table 1: Humidifier Components

Component

Function of Component

Check Valve

Provides back flow protection for supply water line.

Conductivity Sensor

/Transmitter

Sensor measures conductivity of water in the reservoir. Transmitter

sends measured value to control box for use in water quality control.

Control Box /

Display and Keypad

Controls all functions of the humidifier’s operation and provides user

interface for configuration of the humidifier.

Drain Pan

Collects unevaporated water from media for recirculation or draining.

Drain Pan Drain

Drain pan connection to hydraulic unit reservoir.

Drain Outlet

Drain connection from the hydraulic unit.

Drain Overflow

Provides protection from overfilling the drain pan.

Drain Valve

Drains water from the reservoir.

Duct Seal

Prevents duct air flow from bypassing the humidifier.

Fill Valve

Controls makeup water flow to humidifier based on float level.

Float

Measures water level in reservoir to prevent over filling.

Fuse Block

Overcurrent protection for pump and UV light.

High Voltage

Terminal Block

Primary voltage connection on hydraulic unit and in control box.

Hydraulic Unit

Collects water from the drain pan and pumps, treats with UV light, and

stages water to media. Fills and drains reservoir to control water quality.

Intermediate

Member

Structural member supports media boxes.

Low Voltage

Terminal Block

Hydraulic Unit – connects control box inputs to the hydraulic unit.

Control Box – provides connection for control signals and safety loop.

Media Boxes

Surface from which water is evaporated for humidification/cooling.

Mist Eliminator

Captures any water droplets that are carried off the media boxes with air

flow in high duct speed applications.

On/Off Switch

Turns power On/Off to humidifier controller. Note: Turn off humidifier

disconnect to shut off primary power to the humidifier.

Pressure

Equalization Line

Balances pressure in hydraulic unit reservoir with pressure in duct to

ensure proper water flow to reservoir from drain pan.

Pump

Pumps water from the reservoir to the media boxes.

Pump and UV Light

Relay

Turns on power to the UV light and pump based on signal from the

control box.

Reservoir

Collects water from the drain pan for recirculation / draining.

Side Panel, Right

Structural member supports media boxes and spray bar cap.

Spray Bar Cap/

Spray Bars

Distributes water to the media boxes and prevents water from spraying

anywhere else.

Staging Manifold /

Valve(s)

Controls flow of water to media boxes based on demand.

Transformer

Steps primary voltage down to 24 VAC for the controller and internal

components such as the fill valve and drain valve.

UV Light

Eliminates any bacteria in the water being pumped to the media boxes.

Water Lines

Supply water lines from hydraulic unit to spray bars.