NCM Overview

Verilink NCM 2000

1-11

Connectors Used

The EXT management port of the NCM is used to extend the ACP
bus to multiple shelves. Backplane cable connections are used to
extend the TABS bus. The example shown in

Figure 1-6

consists of

four shelves.

Figure 1-6 Cable Diagram for Daisy-chaining Shelves

The NCM in shelf 1 connects to shelf 3 (in this case) through the
EXT connector on the NCM and the PRI connector on the ACP type
card in shelf 3.

Shelf 2 contains all TABS modules. It is extended from Shelf 1 using
the backplane RJ-11 connectors, as in a legacy AS2000 system.

Shelves 3 and 4 have DIDCSU application modules which use the
ACP bus.

Cables for

Connecting

Shelves

The cables used to daisy-chain shelves extend only NCM
management functions, not user data.

Table 1-4

lists the types of

cables used.

NOTE: If a shelf contains both TABS and ACP type modules, use only ACP

type cables to extend the NCM management to that shelf.

Table 1-4

Table 1-4

Table 1-4

Table 1-4 Management Extension Cables

Management Extension Cables

Management Extension Cables

Management Extension Cables

NCM

PRI

EXT

IAD

PRI

EXT

IAD

PRI

EXT

All TABS shelf

RJ-11 backplane cable extends TABS bus

Shelf 1 ACP

Shelf 3 ACP

Shelf 4 ACP

Shelf 2 TABS

Cable Description

Bus

Extended

Cable Part

Number

Cable

Length

Connectors

Control bus expansion cable

TABS

458-501762-002

20”

RJ-11 - RJ-11

Control bus expansion cable

TABS

458-501762-004

40”

RJ-11 - RJ-11

Management bus extension

cable

ACP

458-502313-001

12”

RJ-45 - RJ-45

Management bus extension

cable

ACP

458-502313-008

8’

RJ-45 - RJ-45